Accurate airflow measurement is essential for industrial process control, energy management, and combustion efficiency optimization. In large industrial pipelines, conventional flowmeters may face challenges such as limited installation space, insufficient straight pipe sections, pressure loss, and uneven velocity distribution.
The NY-DH Insertion Type Averaging Multi-Throat Flow Meter is an advanced differential pressure flow measurement device developed on the basis of insertion-type dual-throat flow measurement technology. It combines the high signal strength and anti-blocking performance of dual-throat flow measurement with the advantages of multi-point velocity averaging.
The device consists of multiple specially designed bullet-shaped dual-throat flow sensors. These sensors are arranged at different positions across the pipeline cross-section to collect multiple differential pressure signals. Their high-pressure and low-pressure ports are connected in series to generate an averaged differential pressure output.
This multi-point measurement method provides a more representative measurement of the overall flow velocity distribution inside the pipeline than conventional single-point measurement.
The NY-DH series is particularly suitable for large-diameter air and gas pipelines, including primary air and secondary air measurement in thermal power plants, as well as airflow measurement at coal pulverizer inlets where available straight pipe sections are limited.
The NY-DH averaging multi-throat flow meter operates according to the differential pressure measurement principle and the principle of conservation of energy.
When fluid flows through the specially designed dual-throat sensing elements, a differential pressure is generated between the high-pressure and low-pressure sides. This differential pressure is related to the flow velocity of the fluid.
Unlike conventional single-point differential pressure flowmeters, the NY-DH system uses multiple sensing elements distributed across the pipeline cross-section.
Each sensing element measures the local flow velocity at a specific position. The high-pressure ports and low-pressure ports of the sensors are interconnected separately, allowing the system to obtain an averaged differential pressure signal.
This arrangement helps reduce measurement errors caused by uneven velocity profiles, upstream disturbances, pipe supports, and other flow interference factors.
The basic flow calculation relationships are:
Volumetric Flow Rate:
Qv = Kv × A × f × √(ΔP / ρ)
Mass Flow Rate:
Qm = Km × A × f × √(ΔP / ρ)
Where:
Qv: Volumetric flow rate (m³/h)
Qm: Mass flow rate (kg/h)
Kv: Volumetric flow coefficient
Km: Mass flow coefficient
A: Pipeline cross-sectional area (m²)
f: Fluid structure coefficient
ΔP: Differential pressure (Pa)
ρ: Fluid density (kg/m³)
The actual flow calculation depends on the instrument calibration coefficients and operating conditions.
![]()
Traditional single-point insertion flowmeters measure velocity at only one location, which may not accurately represent the average velocity across a large pipeline.
The NY-DH system uses multiple sensing elements distributed across the pipeline cross-section. By combining their differential pressure signals, it provides a more representative average measurement.
This design is particularly beneficial for large-diameter pipelines where flow velocity distribution may be uneven.
The NY-DH multi-throat flow measurement structure is designed to minimize flow obstruction.
Its pressure loss is approximately one-tenth of that of a conventional orifice plate under comparable operating conditions, according to the product design specifications.
This feature makes it suitable for applications where maintaining system pressure and reducing energy consumption are important.
The multi-sensor arrangement generates a stronger differential pressure signal than a conventional single-point measurement arrangement.
According to the product specifications, the differential pressure signal can be more than twice that of a comparable single-point measurement configuration.
A stronger signal helps improve signal acquisition and measurement stability.
The device adopts a ring-chamber pressure-taking structure, which helps obtain a stable differential pressure output.
The interconnected pressure channels allow multiple measurement points to contribute to the final signal, reducing the influence of local flow fluctuations.
The insertion-type structure makes installation convenient, particularly for large industrial pipelines.
It is suitable for round or rectangular ducts with diameters or equivalent dimensions greater than 500 mm.
Compared with full-bore flow measurement solutions, the insertion structure can reduce installation complexity and is particularly useful for large airflow ducts.
One of the main advantages of the NY-DH system is its ability to operate in pipelines with relatively limited straight pipe sections.
Each measurement point incorporates an internal flow-conditioning structure.
For typical installation arrangements, the recommended straight pipe lengths are:
Single sensor arrangement: approximately 3D upstream and 2D downstream.
Two-sensor arrangement: approximately 0.7–2D upstream and 0.3–0.5D downstream.
Multiple-sensor arrangement: approximately 0.4–1D upstream and 0.3D downstream.
D represents the pipeline diameter.
Actual requirements should be confirmed according to pipeline geometry, flow disturbances, and the selected sensor configuration.
The high-pressure and low-pressure pressure-taking ports are positioned in relatively high-velocity flow regions.
Combined with the ring-chamber pressure-taking structure, this design improves resistance to blockage and helps maintain stable differential pressure transmission.
This is particularly valuable in industrial air systems where dust and suspended particles may be present.
![]()
Primary air is an important part of the coal combustion and pulverizing process in thermal power plants.
Accurate primary air measurement helps operators control the air supply to coal pulverizers, maintain stable pulverized coal transportation, and improve combustion system operation.
The NY-DH insertion type averaging multi-throat flow meter can be installed in large primary air ducts to obtain representative airflow measurements.
Its multi-point sensing structure helps address uneven airflow distribution and limited installation space.
Secondary air provides the oxygen required for efficient fuel combustion in industrial boilers.
Accurate secondary air measurement helps optimize the air-to-fuel ratio, improve combustion efficiency, and support stable boiler operation.
The NY-DH flow measurement device is suitable for large rectangular and circular secondary air ducts.
Its low pressure loss and multi-point averaging measurement principle make it a practical option for boiler airflow monitoring.
Airflow measurement at coal pulverizer inlets can be challenging because of pipeline layout limitations, dust accumulation, and uneven velocity distribution.
Conventional flow measurement devices may require longer straight pipe sections to achieve stable measurement results.
The NY-DH multi-throat flow meter is designed to address these challenges through multiple sensing points and a compact insertion structure.
It can be used to monitor inlet airflow and support the operation and adjustment of coal pulverizing systems.
Large industrial ventilation systems often use rectangular or circular ducts to transport air throughout production facilities.
The NY-DH insertion flow meter can be applied to airflow monitoring in industrial ventilation networks, helping operators understand air distribution and improve system control.
For industrial processes involving large gas pipelines, obtaining a representative flow measurement can be difficult when the velocity profile is uneven.
The NY-DH system provides multi-point differential pressure measurement for air and other suitable gases.
Its insertion-type construction is particularly suitable for large-diameter pipelines where traditional inline flowmeters may be difficult or expensive to install.