Product Details:
|
Probe Rod Length: | 500mm (customizable As Required) | Power Supply: | 24VDC, 220VAC (optional) |
---|---|---|---|
Material: | 316+ Ceramic (optional) | Process Connection: | Screw Thread, Flange(optional), Flanged |
Process Pressure: | < 2.0MPa | Operating Temperature: | > +260 °C |
Protection Grade: | IP67 | Explosion-proof Grade: | Exia IICT6 (optional) |
High Light: | Ceramic Probe RF Admittance Level Switch,RF Admittance Level Switch 500mm,500mm Admittance Type Level Sensor |
NYSP-L863 (High Temperature Type) RF Admittance Switch
Rf admittance switch is also often called rf admittance level meter or RF admittance level meter. Rf admittance is a new level control technology developed from capacitive, which is more reliable, more accurate and more widely applicable. It is an upgrade of capacitive level technology. So-called rf admittance, the meaning of the admittance to the reciprocal of electrical impedance in, its element by resistive, capacitive component, the perceptual component integrated, and radio frequency or high frequency radio spectrum, so the radio frequency admittance can be understood as admittance is measured with a high frequency radio waves. When the instrument is working, the sensor of the instrument forms the admittance value with the tank wall and the measured medium. When the level changes, the admittance value changes accordingly. The circuit unit converts the measured admittance value into the level signal output to realize the level measurement.
NYSP RF Admittance SwitchTechnical Parameter
Applications | liquid,particle, particle, solid position control , especially for high |
Material | 316+ Ceramic (optional)
|
Probe rod length | 500mm (customizable as required) |
Power supply | 24VDC, 220VAC (optional) |
Process temperature | > +260 °C |
Process pressure | < 2.0MPa |
Process connection | Thread, flange (optional) |
Time delay | 0〜30s adjustable |
Power loss protection | open, close, field switchable |
Output relay | double pole, double throw (DPDT) output,5A, 24V DC or 5A, 220VAC |
Protection grade | IP67 |
Explosion-proof grade | Exia IICT6 (optional) |
※ Note: Products can be customized according to the specific requirements of users!
Before connecting RF admittance level switch, make sure that the instrument and power supply are consistent (e. G. 220VAC instrument and 220VAC power supply).
A .Line power supply type (115VA.C or 230VA..C) Ac power line connection: fire line (H), mid line (N) and ground wire (G), if the wire does not have the standard black, white, green three colors, be careful not to confuse the lead. Note: ground must be grounded.
B .DC power supply (24VD.C)
24VDC Power line wire connection: the original (H) end is -24V (+), the original (N) end is the common end (-) and the original (G) end is still the ground wire (G), Note: must be groxinded.
C .Connection of control relay
NYSP Type A relay output contact is type C,two groups of double pole double throw, 10 A,115VA.C, impedance. Light low inductance load can be used for solenoid valve or alarm. Heavy inductance loads must be driven by intermediate relays. The following figure shows the three common connection modes of point level control functions.