Send Message
Home ProductsTuning Fork Density Meter

NYDE - CR Tuning Fork Densitometer For Tank Pipe Density Measurement

Certification
China Xi 'an West Control Internet Of Things Technology Co., Ltd. certification
China Xi 'an West Control Internet Of Things Technology Co., Ltd. certification
I'm Online Chat Now

NYDE - CR Tuning Fork Densitometer For Tank Pipe Density Measurement

NYDE - CR Tuning Fork Densitometer For Tank Pipe Density Measurement
NYDE - CR Tuning Fork Densitometer For Tank Pipe Density Measurement NYDE - CR Tuning Fork Densitometer For Tank Pipe Density Measurement NYDE - CR Tuning Fork Densitometer For Tank Pipe Density Measurement

Large Image :  NYDE - CR Tuning Fork Densitometer For Tank Pipe Density Measurement

Product Details:
Place of Origin: Xi'an, Shaanxi,China
Brand Name: NUOYINGJIAYE
Certification: CE
Model Number: NYDE-CR
Payment & Shipping Terms:
Minimum Order Quantity: 1 pcs
Price: $450 to $1700 /pcs
Packaging Details: Carton, 60cm×30cm×30cm
Delivery Time: 7 working days
Payment Terms: T/T
Supply Ability: 1000 pcs/ pre month

NYDE - CR Tuning Fork Densitometer For Tank Pipe Density Measurement

Description
Typical Application: Tank And Pipe Density Measurement Measuring Range: 0.5~2.5g/cc(500–2500kg/m³)
Power Supply: 24VDC,≥50 MA Signal Output: 4~20 MA,0~1000Hz,RS485 Modbus RTU
Operation Temperature: -50~+200℃ Maximum Working Pressure: 207 Bar (3000 Psi)
Process Connection: ANSI 150 To 1500 RF, DN 50 PN16, DN 50 PN40, IDF And RJT Sanitary Type Housing Type: Electric Blue Cast Aluminum Case, Bright Yellow Cast Aluminum Case, Stainless Steel Case
High Light:

Fork Radar Tank Level Gauge

,

Pipe Tuning Fork Density Meter

,

Tuning Fork Portable Densitometer

Easy To Install And Use Tank And Pipe Density Measurement NYDE-CR Tuning Fork Densitometer

 

NYYC-MD type insertion densitometer can be used for real-time online density detection. It can be used in the process control of products with density as the basic parameter or quality control with solid percentage or concentration percentage as the reference. Using the insertion type installation, widely used in pipelines, open tank containers and closed tank containers in the media density detection fluid density depends directly on the vibration frequency received by the tuning fork inserted into the medium. Sensor built-in temperature sensor to provide temperature compensation. Widely used in petroleum, chemical, brewing, food, pharmaceutical and mineral processing (such as clay, carbonate, silicate, etc.), specific applications in the above industries in the multi-product pipeline interface detection, stirring mixture density detection, reactor endpoint monitoring, ionizer interface detection.

 

NYDE-CR Tuning Fork Densitometer Working Principle

 

The sensor works on the principle of component vibration, the component part being the tuning fork part immersed in the measured liquid. The tuning fork part senses the vibrations through an intrinsic piezoelectric device fixed at the bottom end of the fork body. The vibration frequency is detected by a secondary piezoelectric device fixed at the other end of the fork, and then the signal is amplified by a circuit at the top. The density of the liquid and the frequency of vibration when the measured liquid flows are closely related, and when the density of the measured liquid changes, the frequency of vibration when the liquid flows also changes. Through the equation D=Ko+KIT+KETz, the density of the measured liquid can be calculated accurately.

D = density of the measured medium without calibration (kg/m³)

T = frequency of vibration (μs).

Ko, Ki, K2 = constants

In the density detection process, NYYC-MD plug-in densitometer can automatically compensate for the effect of temperature on the density of the measured medium (D), and the pressure has no significant effect on the density.

 

NYDE-CR Tuning Fork Densitometer Technical Parameters

 

Typical application Tank and pipe density measurement
Housing material Cast aluminum
Measuring range 0.5~2.5g/cc(500–2500kg/m³)
Calibration range 0.5~2.5g/cc(500–2500kg/m³)
Power supply 24VDC,≥50 mA
Signal output 4~20 mA,0~1000Hz,RS485 Modbus RTU
Operation temperature -50~+200℃
Maximum working pressure 207 bar (3000 psi)
Process connection ANSI 150 to 1500 RF, DN 50 PN16, DN 50 PN40, IDF and RJT sanitary type
Joint material 316L, stainless steel, Hastelloy
Fork body coating Standard, PTFE, electrolytic polishing
Protection level IP67
Explosion-proof grade Exia II CT6
Housing Type Electric blue cast aluminum case, bright yellow cast aluminum case, stainless steel case

 

NYDE-CR Tuning Fork Densitometer Design Feature

 

1. Suitable for tanks, pipelines, flowing or stationary media density measurement. Suitable for measuring high temperature, low temperature, high viscosity media containing impurities.

2. Microprocessor-based electronic conversion device, integrating signal processing, calculation and diagnostic functions.

3. Continuous online measurement of liquid density and temperature, high precision, more secure and reliable, can be directly used for production process control.

4. It can communicate directly with PC through RS485 interface, and users can directly perform online node configuration, fault diagnosis and data logging on it.

5. While measuring density and temperature, basic density, concentration percentage, mass percentage, volume percentage and other parameters can be calculated.

6. Excellent overpressure protection structure, superior temperature stability, fully welded seal, robust and reliable design.

7. Easy to install and use, insert the liquid to display the reading.

8. Simplified maintenance, no regular cleaning.

9. Calibration without standard reference source, no laboratory calibration, no process interruption.

10. Intrinsically safe for hazardous sites, hygienic for food production sites.

 

Contact Details
Xi 'an West Control Internet Of Things Technology Co., Ltd.

Contact Person: Winnie

Tel: 17392588557

Send your inquiry directly to us (0 / 3000)